Description
Model |
RG-S2910-24GT4XS-E |
RG-S2910-48GT4XS-E |
RG-S2910-10GT2SFP-P-E |
RG-S2910C-24GT2XS-HP-E |
RG-S2910C-48GT2XS-HP-E |
Ports |
24 10/100/1000BASE-T ports |
48 10/100/1000BASE-T ports |
10 10/100/1000BASE-T ports 2 100/1000BASE-X SFP ports (non-combo) |
24 10/100/1000BASE-T ports (PoE/PoE+) |
48 10/100/1000BASE-T ports (PoE/PoE+) |
Expansion Slots |
N/A |
N/A |
N/A |
2 |
2 |
Modular Power Slots |
N/A |
N/A |
N/A |
2 |
2 |
Fan Slots |
Fixed |
Fixed |
Fanless |
Fixed |
Fixed |
Expansion Modules |
N/A |
N/A |
N/A |
M2910-01XS |
M2910-01XS |
Management Ports |
1 console port |
1 console port |
1 console port |
1 console port |
1 console port |
Switching Capacity |
264Gbps |
264Gbps |
256Gbps |
264Gbps |
264Gbps |
Packet Forwarding Rate |
96Mpps |
132Mpps |
18Mpps |
96Mpps |
132Mpps |
Max. Number of 10GE Ports |
4 |
4 |
N/A |
4 |
4 |
PoE |
N/A |
N/A |
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking |
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking |
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking |
Port Buffer |
1.5MB |
||||
RAM |
512MB |
||||
ARP Table |
1,000 |
1,000 |
500 |
1,000 |
1,000 |
MAC Address |
16K |
||||
Routing Table Size |
500 (IPv4/IPv6) |
500 (IPv4/IPv6) |
64 (IPv4/IPv6) |
500 (IPv4/IPv6) |
500 (IPv4/IPv6) |
ACL Entries |
In: 1,500 |
In: 1,500 |
In: 750 Out: N/A |
In: 1,500 |
In: 1,500 |
VLAN |
4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN |
||||
QinQ |
Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching |
||||
Link Aggregation |
AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance |
||||
Port Mirroring |
Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN # RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring |
||||
Spanning Tree Protocols |
IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG) |
||||
DHCP |
DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82 |
||||
Multiple Spanning Tree Protocol (MSTP) Instances |
64 |
||||
Maximum Aggregation Port (AP) |
128 |
||||
SDN |
OpenFlow 1.0 & 1.3 |
||||
VSU (Virtual Switch Unit) |
Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports # All models support the features above except RG-S2910-10GT2SFP-P-E |
||||
Zero Configuration |
CWMP(TR069) |
||||
L2 Features |
MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel |
||||
Layer 2 Protocols |
IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s |
||||
IPv4 Features |
Ping, Traceroute |
||||
IPv6 Features |
ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address |
||||
IPv4 Routing Protocols |
Static Routing, RIP, OSPF v1/v2 |
||||
Basic IPv6 Protocols |
IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert |
||||
IPv6 Routing Protocols |
Static routing, RIPng, OSPF v3 |
||||
G.8032 |
Support |
||||
ACL |
Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL, Router ACL, VLAN ACL, Port-Based ACL |
||||
QoS |
802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS |
||||
Reliability |
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) |
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) |
RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) |
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
EEE Format |
Support IEEE 802.3az standard |
||||
Security |
Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI) |
||||
Manageability |
SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS # RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web
|
||||
Hot Patch |
Support |
||||
Smart Temperature Control |
Auto fan speed adjustment; Fan malfunction alerts; Fan status check # All models support the features above except RG-S2910-10GT2SFP-P-E
|
||||
Smart Power Supply |
N/A |
N/A |
N/A |
Support power control and management |
Support power control and management |
Other Protocols |
FTP, TFTP, DNS client, DNS static |
||||
Dimensions |
440 × 260 × 43.6 |
440 × 260 × 43.6 |
340 × 260 × 44 |
440 × 320 × 44 |
440 × 360 × 44 |
Rack Height |
1RU |
||||
Weight |
≤3.5kg |
≤4kg |
<2.5kg |
5.8kg (gross weight) |
6.8kg (gross weight) |
MTBF (hours) |
>200K |
||||
Lightning Protection on Power Port |
Common Mode 6KV/Differential Mode 6KV | Common Mode 6KV/Differential Mode 6KV | Common Mode 6KV/Differential Mode 6KV | Common Mode 4KV/Differential Mode 2K | Common Mode 4KV/Differential Mode 2K |
Lightening Protection on Communication Port |
Common Mode 6KV | ||||
Power Supply |
AC input: HVDC input: |
AC input: HVDC input: |
AC input: Rated voltage range: 100V to 240V AC Maximum voltage range: 90V to 264V AC Frequency: 50/60Hz Rated current: 2A
HVDC input: |
AC power (RG-M5000E-AC500P): HVDC input: DC power (RG-M5000E-DC500P): AC power (RG-RG-PA1150P-F): HVDC input: |
AC power (RG-M5000E-AC500P): HVDC input: DC power (RG-M5000E-DC500P): AC power (RG-RG-PA1150P-F): HVDC input: |
Power Consumption |
24W |
50W |
165W (with 8-port PoE or 4-port PoE+) |
850W (with 24-port PoE+) |
1700W (with 48-port PoE+) |
PoE Power |
N/A |
N/A |
125W |
RG-M5000E-AC500P: 370W |
RG-M5000E-AC500P: 370W |
Safety Standards |
IEC 60950-1, EN 60950-1 |
||||
Emission Standards |
EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 |
||||
Temperature |
Operating temperature: 0°C to 50°C |
Operating temperature: 0°C to 50°C |
Operating temperature: 0°C to 45°C |
Operating temperature: 0°C to 50°C |
Operating temperature: 0°C to 50°C |
Storage temperature: -40°C to 70°C |
|||||
Humidity |
Operating humidity: 10% to 90%RH |
||||
Storage humidity: 5% to 95%RH |
|||||
Operating Altitude |
-500m to 5,000m |
Reviews
There are no reviews yet.