Description
Hardware Specifications
Hardware Specifications | RG-CS86-20XS4VS2QXS-D |
Interface Specifications | |
Fixed Ports | 20 x 1GE/2.5GE/10GE SFP+ ports, 4 x 10G/25G SFP28 ports, 2 x 40G QSFP+ ports. One switch provides a maximum of 32 x 10G ports, 2 modular power slots, and 2 modular fan slots. |
Fan modules | Dual pluggable modular fans, with front-to-rear ventilation channels
Fan speed regulating and alarm function |
Power modules | 2 replaceable hot-swappable power supply slots |
Fixed management ports | One MGMT port, one console port, and one USB port |
System Specifications | |
Forwarding Rate | 570 Mpps/1260 Mpps |
Switching Capacity | 2.56 Tbps |
MAC Table Capacity | 32,768 |
ARP table | 16,000 |
IPv4 Unicast Routes | 16,000 |
IPv4 Multicast Routes | 4,000 |
IPv6 Unicast Routes | 2,000 |
IPv6 Multicast Routes | 16,000 |
ACL entries | In: 2,500
Out:1,000 |
Number of VSU members | 4 |
Dimensions and Weight | |
Dimensions (W x D x H) | 440 x 330 x 43.6 mm (17.32 x 12.99 x 1.72 in), 1 RU |
Weight of the empty chassis | 4.6 kg (10.14 lbs) |
CPU and Storage | |
CPU | Dual-core CPU, 1.25GHz |
Storage | Flash memory: 1 GB
SDRAM: 1 GB |
Power and Consumption | |
Power Supply | Supported power module type: RG-PA150I-F
AC input: Rated voltage range: 100–240 V AC; 50/60 Hz Maximum voltage range: 90–264 V AC; 47/63 Hz Rated input current: 3 A
HVDC input: Rated voltage: 240 V DC Maximum voltage range: 192–288 V AC Rated current per circuit: 3 A
|
Environment and Reliability | |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Operating humidity | 10% to 90% RH (non-condensing) |
Storage humidity | 5% to 95% RH (non-condensing) |
Interface surge protection | Power port: 6 kV/6 kV
Telecom port: 10 kV (MGMT port: 4 kV) |
Temperature Alarm | Supported |
Software Specifications
RG-CS86-20XS4VS2QXS-D | |
Feature | Description |
Ethernet Switching | Jumbo frame (maximum length: 9,216 bytes) |
IEEE 802.1Q (supporting 4K VLANs) | |
Voice VLAN | |
Super VLAN, Private VLAN | |
MAC VLAN, Port based VLAN, Protocol based VLAN, IP-Subnet based VLAN | |
GVRP | |
Basic QinQ | |
STP, RSTP, and MSTP | |
ERPS (G.8032) | |
LLDP/LLDP-MED | |
LACP (IEEE 802.3ad) | |
IP Service | ARP |
DHCP client, DHCP relay, and DHCP server | |
DHCP snooping | |
DNS | |
DHCPv6 client and DHCPv6 relay | |
DHCPv6 snooping | |
Neighbor Discovery (ND) and ND snooping | |
IP Routing | Static routing |
RIP and RIPng | |
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 | |
BGP4 and BGP4+ | |
IPv4 and IPv6 VRF | |
IPv4 and IPv6 PBR | |
Equal and Weighted Cost Multi-Path (ECMP) | |
Multicast | IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2/v3 snooping | |
PIM-DM, PIM-SM, and PIM-SSM | |
MSDP | |
MLD v1/v2 | |
MLD snooping v1/v2 | |
PIM-SMv6 and PIM-SSM v6 | |
IGMP filtering, IGMP immediate leave | |
ACL and QoS | Standard IP ACLs
Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
ACL redirection | |
Port traffic rate limiting | |
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | |
Congestion avoidance: tail drop, RED, and WRED | |
802.1p/DSCP/ToS traffic classification
Eight priority queues per port |
|
Security | Multiple AAA modes |
RADIUS and TACAS+ | |
Port-based and MAC-based 802.1x authentication | |
Web authentication | |
HTTPS | |
SSHv1, SSHv2 | |
Global IP-MAC binding | |
Port isolation and port security | |
IP source guard | |
SAVI | |
CPP and NFPP | |
Strict and loose RPF | |
Reliability | REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP | |
BFD | |
Hot swapping of power modules and cables | |
3-level fan speed adjustment
Fan fault alarm |
|
Device virtualization | Virtual Switching Unit (VSU) |
NMS and maintenance | SPAN, RSPAN, and ERSPAN |
sFLOW | |
NTP and SNTP | |
FTP and TFTP | |
SNMP v1/v2/v3 | |
RMON (1, 2, 3, 9) | |
Telnet | |
NETCONF | |
CWMP (TR-069) standard protocol | |
gRPC | |
Cloud and SON |
Reviews
There are no reviews yet.