Hardware Specifications
| Hardware Specifications | RG-CS83-24GT4XS-PD | RG-CS83-48GT4XS-PD |
| Interface Specifications | ||
| Fixed ports | 24 x 10/100/1000 BASE-T ports
4 x 1G/10G SFP+ ports PoE standards: IEEE 802.3af and 802.3at |
48 x 10/100/1000 BASE-T ports
4 x 1G/10G SFP+ ports PoE standards: IEEE 802.3af and 802.3at |
| Fans | Fixed fans | Fixed fans |
| Power supplies | RG-PA600I-P-F: 600 W (PoE: 370 W), 0.9 kg
RG-PA1000I-P-F: 176-290 V AC 1000 W; 90-176 V AC 930 W (PoE: 740 W); 1 kg Power supplies in redundancy mode |
RG-PA600I-P-F: 600 W (PoE: 370 W), 0.9 kg
RG-PA1000I-P-F: 176-290 V AC 1000 W; 90-176 V AC 930 W (PoE: 740 W); 1 kg Power supplies in redundancy mode |
| Fixed management ports | 1 x MGMT port, 1 x console port, and 1 x USB port | 1 x MGMT port, 1 x console port, and 1 x USB port |
| System Specifications | ||
| Forwarding rate | 96 Mpps | 132 Mpps |
| System Switching capacity | 336 Gbps | 432 Gbps |
| MAC address | 32K | |
| ARP table | 4K | |
| Routing table size (IPv4) | 8K | |
| Routing table size (IPv6) | 4K | |
| ACL entries | In: 3500
Out:1500 |
|
| Number of VSU members | 4 | |
| Dimensions and Weight | ||
| Dimensions (W x D x H) | 442 mm x 420 mm x 43.6 mm | |
| Package dimensions (W x D x H) | 570 mm x 565 mm x 172 mm | |
| Weight of the empty chassis | 4.3 kg | 4.6 kg |
| Package weight | 6.78 kg | 6.98 kg |
| CPU and Storage | ||
| CPU | Dual cores, with the clock speed of 1.2 GHz | |
| Storage | Flash memory: 2 GB
SDRAM: 1 GB |
|
| Power and Consumption | ||
| Maximum power consumption | < 65 W (non-PoE)
< 810 W (PoE full load) |
< 75 W (non-PoE)
< 1570 W (PoE full load) |
| Maximum output power | RG-PA600I-P-F: 600 W (PoE: 370 W)
RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000W 90 V AC to 176 V AC, 930 W (PoE: 740 W) |
|
| Rated input voltage | RG-PA600I-P-F:
AC: 100 V AC to 240 V AC, 50/60 Hz HVDC: 240 V DC RG-PA1000I-P-F: AC: 100 V AC to 240 V AC, 50/60 Hz HVDC: 240 V DC |
|
| Maximum input voltage | RG-PA600I-P-F:
AC: 90 V AC to 264 V AC, 47/63 Hz HVDC: 192 V DC to 288 V DC RG-PA1000I-P-F: AC: 90 V AC to 264 V AC, 47/63 Hz HVDC: 192 V DC to 288 V DC |
|
| Environment and Reliability | ||
| MTBF | ≥ 356,000 hours (dual power modules)
≥ 208,000 hours (single power module) |
≥ 315,000 hours (dual power modules)
≥ 193,000 hours (single power module) |
| Heat dissipation | Left-to-right and front-to-right airflow | |
| Operating temperature | 0°C to 45°C (32°F to 115°F) | |
| Storage temperature | -40°C to +70°C (-40°F to +158°F) | |
| Operating humidity | 10% to 90% RH (non-condensing) | |
| Storage humidity | 5% to 95% RH (non-condensing) | |
| Operating noise | 27°C: 51.6 dB
45°C: 57.4 dB |
27°C: 51.6 dB
45°C: 58.3 dB |
| Interface surge protection | Power port: 6 kV/6 kV
Telecom port: 10 kV (MGMT port: 4 kV) |
Power port: 6 kV/6 kV
Telecom port: 10 kV (MGMT port: 4 kV) |
Software Specifications
| RG-CS83-PD Series | |
| Feature | Description |
| Ethernet switching | Jumbo frame (maximum length: 9216 bytes) |
| IEEE 802.1Q (4K VLANs) | |
| Voice VLAN | |
| Super VLAN and private VLAN | |
| MAC VLAN, port-based VLAN, protocol-based VLAN, and IP-subnet based VLAN | |
| GVRP | |
| Basic QinQ
Selective QinQ |
|
| STP, RSTP, and MSTP | |
| ERPS (G.8032) | |
| LLDP/LLDP-MED | |
| LACP (IEEE 802.3ad) | |
| IP service | ARP |
| DHCP client, DHCP relay, and DHCP server | |
| DHCP snooping | |
| DNS | |
| DHCPv6 client and DHCPv6 relay | |
| DHCPv6 snooping | |
| Neighbor Discovery (ND) and ND snooping | |
| IP routing | Static routing |
| RIP, RIPng | |
| OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 | |
| IPv4 and IPv6 VRF | |
| IPv4 and IPv6 PBR | |
| Multicast | IGMP v1/v2/v3, and IGMP proxy |
| IGMP v1/v2/v3 snooping | |
| PIM-DM, PIM-SM, and PIM-SSM | |
| MSDP | |
| MLD v1/v2 | |
| MLD snooping v1/v2 | |
| PIM-SMv6, PIM-SSM v6 | |
| ACL and QoS | Standard IP ACLs
Extended IP ACLs Extended MAC ACLs ACL80 IPv6 ACL |
| ACL redirection | |
| Port traffic identification | |
| Port traffic rate limiting | |
| 802.1p/DSCP/ToS traffic classification
Eight priority queues per interface |
|
| Traffic policing: CAR | |
| Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | |
| Congestion avoidance: tail drop, RED, and WRED | |
| Rate limiting in each queue | |
| Security | Multiple AAA modes |
| RADIUS and TACAS+ | |
| Port-based and MAC-based 802.1x authentication | |
| Web authentication | |
| Allowlist | |
| HTTPS | |
| SSHv1, SSHv2 | |
| Global IP-MAC binding | |
| ICMP (the port discards ICMP packets of which the rate exceeds the configured threshold) | |
| Port isolation and port security | |
| IP Source Guard | |
| SAVI | |
| Gateway ARP anti-spoofing | |
| CPP(CPU Protection Policy) | |
| NFPP( Network Foundation Protection Policy) | |
| Strict and loose RPF
uRPF ignoring default routes |
|
| Reliability | REUP, RLDP, DLDP |
| IPv4 VRRP v2/v3 and IPv6 VRRP | |
| BFD | |
| Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) | |
| Hot swapping of power modules and cables | |
| 3-level fan speed adjustment
Fan fault alarm |
|
| Device virtualization | Virtual Switching Unit (VSU) |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| sFlow | |
| NTP and SNTP | |
| FTP and TFTP | |
| SNMP v1/v2/v3 | |
| RMON (1, 2, 3, 9) | |
| NETCONF | |
| CWMP (TR-069) standard protocol | |
| gRPC | |
| Cloud and SON | |
| PoE | IEEE 802.3af and 802.3at
Uninterruptible power supply upon hot start Port priority |