RG-CS86-20XS4VS2QXS-D

RG-CS86-20XS4VS2QXS-D

Highlight Features

  • 20 x 10GE SFP+ ports, 4 x 25GE SFP28 ports, and 2 x 40GE QSFP+ ports for uplink
  • VSU, realizing flexible networking and high performance
  • Hardware-level multi-protection, ensuring service continuity
  • Network security policies and real-time monitoring, enhancing network robustness
  • Comprehensive QoS policies for flexible network resource allocation and stable services
  • Diverse network management modes, enabling simple maintenance

Hardware Specifications

Hardware SpecificationsRG-CS86-20XS4VS2QXS-D
Interface Specifications
Fixed Ports20 x 1GE/2.5GE/10GE SFP+ ports, 4 x 10G/25G SFP28 ports, 2 x 40G QSFP+ ports. One switch provides a maximum of 32 x 10G ports, 2 modular power slots, and 2 modular fan slots.
Fan modulesDual pluggable modular fans, with front-to-rear ventilation channels

Fan speed regulating and alarm function

Power modules2 replaceable hot-swappable power supply slots
Fixed management portsOne MGMT port, one console port, and one USB port
System Specifications
Forwarding Rate570 Mpps/1260 Mpps
Switching Capacity2.56 Tbps
MAC Table Capacity32,768
ARP table16,000
IPv4 Unicast Routes16,000
IPv4 Multicast Routes4,000
IPv6 Unicast Routes2,000
IPv6 Multicast Routes16,000
ACL entriesIn: 2,500

Out:1,000

Number of VSU members4
Dimensions and Weight
Dimensions (W x D x H)440 x 330 x 43.6 mm (17.32 x 12.99 x 1.72 in), 1 RU
Weight of the empty chassis4.6 kg (10.14 lbs)
CPU and Storage
CPUDual-core CPU, 1.25GHz
StorageFlash memory: 1 GB

SDRAM: 1 GB

Power and Consumption
Power SupplySupported power module type: RG-PA150I-F

AC input:

Rated voltage range: 100–240 V AC; 50/60 Hz

Maximum voltage range: 90–264 V AC; 47/63 Hz

Rated input current: 3 A

 

HVDC input:

Rated voltage: 240 V DC

Maximum voltage range: 192–288 V AC

Rated current per circuit: 3 A

 

Environment and Reliability
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-40°C to +70°C (-40°F to +158°F)
Operating humidity10% to 90% RH (non-condensing)
Storage humidity5% to 95% RH (non-condensing)
Interface surge protectionPower port: 6 kV/6 kV

Telecom port: 10 kV (MGMT port: 4 kV)

Temperature AlarmSupported


Software S
pecifications

RG-CS86-20XS4VS2QXS-D
FeatureDescription
Ethernet SwitchingJumbo frame (maximum length: 9,216 bytes)
IEEE 802.1Q (supporting 4K VLANs)
Voice VLAN
Super VLAN, Private VLAN
MAC VLAN, Port based VLAN, Protocol based VLAN, IP-Subnet based VLAN
GVRP
Basic QinQ
STP, RSTP, and MSTP
ERPS (G.8032)
LLDP/LLDP-MED
LACP (IEEE 802.3ad)
IP ServiceARP
DHCP client, DHCP relay, and DHCP server
DHCP snooping
DNS
DHCPv6 client and DHCPv6 relay
DHCPv6 snooping
Neighbor Discovery (ND) and ND snooping
IP RoutingStatic routing
RIP and RIPng
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6
BGP4 and BGP4+
IPv4 and IPv6 VRF
IPv4 and IPv6 PBR
Equal and Weighted Cost Multi-Path (ECMP)
MulticastIGMP v1/v2/v3, and IGMP proxy
IGMP v1/v2/v3 snooping
PIM-DM, PIM-SM, and PIM-SSM
MSDP
MLD v1/v2
MLD snooping v1/v2
PIM-SMv6 and PIM-SSM v6
IGMP filtering, IGMP immediate leave
ACL and QoSStandard IP ACLs

Extended IP ACLs

Extended MAC ACLs

Time-based ACLs

Expert-level ACLs

ACL80

IPv6 ACL

ACL redirection
Port traffic rate limiting
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ
Congestion avoidance: tail drop, RED, and WRED
802.1p/DSCP/ToS traffic classification

Eight priority queues per port

SecurityMultiple AAA modes
RADIUS and TACAS+
Port-based and MAC-based 802.1x authentication
Web authentication
HTTPS
SSHv1, SSHv2
Global IP-MAC binding
Port isolation and port security
IP source guard
SAVI
CPP and NFPP
Strict and loose RPF
ReliabilityREUP, RLDP, DLDP
IPv4 VRRP v2/v3 and IPv6 VRRP
BFD
Hot swapping of power modules and cables
3-level fan speed adjustment

Fan fault alarm

Device virtualizationVirtual Switching Unit (VSU)
NMS and maintenanceSPAN, RSPAN, and ERSPAN
sFLOW
NTP and SNTP
FTP and TFTP
SNMP v1/v2/v3
RMON (1, 2, 3, 9)
Telnet
NETCONF
CWMP (TR-069) standard protocol
gRPC
Cloud and SON