Model | RG-S2910-24GT4XS-E | RG-S2910-48GT4XS-E | RG-S2910-10GT2SFP-P-E | RG-S2910C-24GT2XS-HP-E | RG-S2910C-48GT2XS-HP-E |
Ports | 24 10/100/1000BASE-T ports | 48 10/100/1000BASE-T ports | 10 10/100/1000BASE-T ports 2 100/1000BASE-X SFP ports (non-combo) | 24 10/100/1000BASE-T ports (PoE/PoE+) | 48 10/100/1000BASE-T ports (PoE/PoE+) |
Expansion Slots | N/A | N/A | N/A | 2 | 2 |
Modular Power Slots | N/A | N/A | N/A | 2 | 2 |
Fan Slots | Fixed | Fixed | Fanless | Fixed | Fixed |
Expansion Modules | N/A | N/A | N/A | M2910-01XS | M2910-01XS |
Management Ports | 1 console port | 1 console port | 1 console port | 1 console port | 1 console port |
Switching Capacity | 264Gbps | 264Gbps | 256Gbps | 264Gbps | 264Gbps |
Packet Forwarding Rate | 96Mpps | 132Mpps | 18Mpps | 96Mpps | 132Mpps |
Max. Number of 10GE Ports | 4 | 4 | N/A | 4 | 4 |
PoE | N/A | N/A | IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking | IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking | IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking |
Port Buffer | 1.5MB | ||||
RAM | 512MB | ||||
ARP Table | 1,000 | 1,000 | 500 | 1,000 | 1,000 |
MAC Address | 16K | ||||
Routing Table Size | 500 (IPv4/IPv6) | 500 (IPv4/IPv6) | 64 (IPv4/IPv6) | 500 (IPv4/IPv6) | 500 (IPv4/IPv6) |
ACL Entries | In: 1,500 | In: 1,500 | In: 750 Out: N/A | In: 1,500 | In: 1,500 |
VLAN | 4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN | ||||
QinQ | Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching | ||||
Link Aggregation | AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance | ||||
Port Mirroring | Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN # RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring | ||||
Spanning Tree Protocols | IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG) | ||||
DHCP | DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82 | ||||
Multiple Spanning Tree Protocol (MSTP) Instances | 64 | ||||
Maximum Aggregation Port (AP) | 128 | ||||
SDN | OpenFlow 1.0 & 1.3 | ||||
VSU (Virtual Switch Unit) | Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports # All models support the features above except RG-S2910-10GT2SFP-P-E | ||||
Zero Configuration | CWMP(TR069) | ||||
L2 Features | MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel | ||||
Layer 2 Protocols | IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s | ||||
IPv4 Features | Ping, Traceroute | ||||
IPv6 Features | ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address | ||||
IPv4 Routing Protocols | Static Routing, RIP, OSPF v1/v2 | ||||
Basic IPv6 Protocols | IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert | ||||
IPv6 Routing Protocols | Static routing, RIPng, OSPF v3 | ||||
G.8032 | Support | ||||
ACL | Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL, Router ACL, VLAN ACL, Port-Based ACL | ||||
QoS | 802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS | ||||
Reliability | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
EEE Format | Support IEEE 802.3az standard | ||||
Security | Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI) | ||||
Manageability | SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS # RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web | ||||
Hot Patch | Support | ||||
Smart Temperature Control | Auto fan speed adjustment; Fan malfunction alerts; Fan status check # All models support the features above except RG-S2910-10GT2SFP-P-E | ||||
Smart Power Supply | N/A | N/A | N/A | Support power control and management | Support power control and management |
Other Protocols | FTP, TFTP, DNS client, DNS static | ||||
Dimensions | 440 × 260 × 43.6 | 440 × 260 × 43.6 | 340 × 260 × 44 | 440 × 320 × 44 | 440 × 360 × 44 |
Rack Height | 1RU | ||||
Weight | ≤3.5kg | ≤4kg | <2.5kg | 5.8kg (gross weight) | 6.8kg (gross weight) |
MTBF (hours) | >200K | ||||
Lightning Protection on Power Port | Common Mode 6KV/Differential Mode 6KV | Common Mode 6KV/Differential Mode 6KV | Common Mode 6KV/Differential Mode 6KV | Common Mode 4KV/Differential Mode 2K | Common Mode 4KV/Differential Mode 2K |
Lightening Protection on Communication Port | Common Mode 6KV | ||||
Power Supply | AC input: HVDC input: | AC input: HVDC input: | AC input: Rated voltage range: 100V to 240V AC Maximum voltage range: 90V to 264V AC Frequency: 50/60Hz Rated current: 2A HVDC input: | AC power (RG-M5000E-AC500P): HVDC input: DC power (RG-M5000E-DC500P): AC power (RG-RG-PA1150P-F): HVDC input: | AC power (RG-M5000E-AC500P): HVDC input: DC power (RG-M5000E-DC500P): AC power (RG-RG-PA1150P-F): HVDC input: |
Power Consumption | 24W | 50W | 165W (with 8-port PoE or 4-port PoE+) | 850W (with 24-port PoE+) | 1700W (with 48-port PoE+) |
PoE Power | N/A | N/A | 125W | RG-M5000E-AC500P: 370W | RG-M5000E-AC500P: 370W |
Safety Standards | IEC 60950-1, EN 60950-1 | ||||
Emission Standards | EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 | ||||
Temperature | Operating temperature: 0°C to 50°C | Operating temperature: 0°C to 50°C | Operating temperature: 0°C to 45°C | Operating temperature: 0°C to 50°C | Operating temperature: 0°C to 50°C |
Storage temperature: -40°C to 70°C | |||||
Humidity | Operating humidity: 10% to 90%RH | ||||
Storage humidity: 5% to 95%RH | |||||
Operating Altitude | -500m to 5,000m |